Summit Environmental Technologies prides itself in its expansive testing capabilities in a variety of different fields. To find out if Summit conducts this test, contact us at 330-253-8211 today.
View Actual EPA Method 629 (PDF File)
EPA Method 629:The Determination of Cyanazine in Municipal and Industrial Wastewater
Summary:A measured volume of sample, approximately 1 L, is extracted with methylene chloride using a separatory funnel. The methylene chloride extract is dried and exchanged to methanol during concentration to a volume of 10 mL or less. HPLC conditions are described which permit the separation and measurement of cyanazine in the extract by HPLC with a UV detector.
Scope:This method covers the determination of cyanazine.
Report Number:821/R-93-010-A