EPA Method 900

Summit Environmental Technologies prides itself in its expansive testing capabilities in a variety of different fields. To find out if Summit conducts this test, contact us at 330-253-8211 today.

PDF IconView Actual EPA Method 900 (PDF File)


EPA Method 900:
Gross Alpha and Beta Activity in Water. Official Name: Gross Alpha and Gross Beta Radioactivity in Drinking Water

Summary:
An aliquot of a preserved drinking water sample is evaporated to a small volume and transferred quantitatively to a tared 2-inch stainless steel counting planchet. The sample residue is dried to constant weight, reweighed to determine dry residue weight, then counted for alpha and/or beta radioactivity. Counting efficiencies for both alpha and beta particle activities are selected according to the amount of sample solids from counting efficiency vs sample solids standard curves.

Scope:
This method is a screening technique that covers the measurement of gross alpha and gross beta particle activities in drinking water. This method covers the measurement of gross alpha and gross beta particle activities in drinking water. The method is a screening technique for monitoring drinking water supplies for alpha and beta particle activities according to the limits set forth under the Safe Drinking Water Act, PL 93-523, 40 FR 34324, and thereby determining the necessity for further analysis.The method is applicable to the measurement of alpha emitters having energies above 3.9 megaelectronvolts (MeV) and beta emitters having maximum energies above 0.1 MeV. For drinking waters with an extremely high solids content (>500 ppm), method 900.1 is recommended.

Citation:
Prescribed Procedures for Measurement of Radioactivity in Drinking Water (EPA/600/4-80-032), August, 1980.

Interferences:
(1) Moisture absorbed by the sample residue. (2) Non-uniformity of sample residue in counting planchet. (3) Sample density on planchet area should not be more than 5 mg/cm2 for gross alpha and 10 mg/cm2 for gross beta. (4) Discrimination against beta/alpha activity by gas flow proportional counting.

QC Requirements:
Not Included

Media:
WATER

Subcategory:
Radiochemical

Concentration:
Alpha: 1 pCi/L - * Beta: 4 pCi/L - * (* Method does not specify an upper detection limit.)

Precision:
-

Detection:
MDLs are the limits that are required for compliance with drinking water regulations (for which this method was designed).

Revision Number:
Aug-80