EPA Method 9215

Summit Environmental Technologies prides itself in its expansive testing capabilities in a variety of different fields. To find out if Summit conducts this test, contact us at 330-253-8211 today.

PDF IconView Actual EPA Method 9215 (PDF File)


EPA Method 9215:
POTENTIOMETRIC DETERMINATION OF SULFIDE IN AQUEOUS SAMPLES AND DISTILLATES WITH ION-SELECTIVE ELECTRODE

Summary:
The distillations in Methods 9030 and/or 9031 are performed, except that the scrubber solution is sulfide anti-oxidant buffer (SAOB), with ascorbic and salicylic acids added as oxygen scavengers. The distillates are then analyzed potentiometrically using a sulfide ion-selective electrode (ISE) in conjunction with a double-junction reference electrode and a pH meter with an expanded millivolt scale or an ISE meter capable of being calibrated directly in terms of sulfide concentration.

Scope:
This method can be used for measuring total sulfide in a distilled sample. The method is meant to be used as an alternate determinative step following the distillation in either SW- 846 Methods 9030 or 9031.

Report Number:
SW-846 Ch 5